Four object families.
Replay the learned behavior.
4 families · 8 training assets total 80k / 90k / 100k × 2 environments per family 24 saved rollouts · 600 steps each
These saved trajectories are comparisons, not a quantitative study of success rates or generalization to unseen objects.
One finger tracing
the joint workspace.
Move the index finger or thumb. Overlay fingertip trajectories from independent joint limits and the existing reachability table.
Two sliders create motion.
Their limits shape the reach.
Common motion produces pitch; a difference produces roll. An original finger mounted at the mechanism output shows when commands reach the model limits.
Mechanism sources and scope
Pivots, attachment points and rod lengths are reconstructed from the vendor kinematic dimensions and equations. LM guide, block and support shapes are illustrative. The original four finger links are mounted at the MCP output pivot after aligning mechanism and URDF coordinates. The hand and mounted finger share the same orientation and joint motion. This placement is explanatory, not a reconstruction of measured internal mounting CAD.
The existing constraint model includes slider stroke, differential travel and the valid kinematic domain. These limits do not all imply physical collisions at the LM guide ends. The differential envelope comes from earlier right-hand logs; its correspondence to physical interference in the current left hand is unverified. This view uses left-hand calibration for a kinematic explanation. Physical dimensions and interference require separate validation.
Dimensions · Calculated motion · Sources ↗Drop onto an open hand.
Compare holding and sliding.
Keep the palm and all five fingers open. Release the same large object from the same height, and compare contact pads at the selected inclination.
The entire hand stays open (q=0), fixed at the selected angle from the start; the default is −15°. The object is centered over the middle and distal segments of the four fingers, with its base parallel to the hand. Both conditions share the same palm and finger collision shells. ON adds 15 pad colliders and high-friction material.
Pads disabled
Shell μ 0.25Pads enabled
Pads μ 1.50Experiment scope and all conditions
This passive drop-and-support test fixes the original left palm and five fingers in the open pose (q=0). Initial object pose, mass, clearance, gravity and hand motion are identical. Only ON adds the original 15 convex pad hulls and high-friction material. The experiment does not test active grasping or physical joint compliance.
MuJoCo uses its default friction combination rule (shell–object 0.5, pad–object 1.5); contact calculations differ from Isaac/PhysX. An object is marked retained if it avoids the floor for 6 seconds and ends in contact with the hand with its center above 100 mm.
Trajectories · Contacts · Source hashes ↗